Place of Origin: | Shenzhen |
---|---|
Brand Name: | Canroon |
Certification: | CE ISO9001:2008 |
Model Number: | CV900 Series variable frequency drive |
Minimum Order Quantity: | 1SET |
Price: | 200USD-20000USD |
Packaging Details: | depend on our customers |
Delivery Time: | A week after confirmed payment |
Payment Terms: | L/C,T/T,Western Union |
Supply Ability: | 2000 Piece/Pieces per Week |
Name: | Variable Frequency Drive | Input: | 3-phrase, 320V~460V, 50/60Hz |
---|---|---|---|
Adapted Motor: | 0.7~160kW | ||
High Light: | high frequency inverter,variable frequency drive |
CV900 high-performance vector control VFD (variable frequency drive) included advanced technology of electric vector control. High torque output of full frequency, quick response, perfect load adaptability, high control precision of speed and good reliability, all of which made it an ideal choice of universal high-performance frequency inverter which can meet high requirement during field operation.
Input |
Rated Voltage, Frequency |
Three phrase (4T#series) 380V; 50/60Hz | |||
Allowed Voltage Range |
Three phrase (4T#series) 320V~460V | ||||
Output | Voltage | 4T# series; 0~380V | |||
Frequency | Low frequency mode: 0~300 Hz; High frequency mode: 0~3000Hz | ||||
Overload Capacity |
G type: 110% for long-term, 150% for 1 min, 180% for 5s P type: 105% for long-term, 120% for 1 min, 150% for 1s |
||||
Control Mode |
V/F control, advanced V/F control, V/F separation control, electric current vector control |
||||
C O N T R O L
C H A R A C T E R
|
Frequency Setting Resolution |
Analog Input | 0.1% of maximum output frequency | ||
Digital Setting | 0.01 Hz | ||||
Frequency Precision | Analog Input |
Within 0.2% of maximum output frequency |
|||
Digital Setting | Within 0.01% of set output frequency | ||||
V/F Control |
V/F Curve (voltage frequency character) |
Reference frequency setting 5~600 Hz, multipoint V/F curve setting, or fixed curve of constant torque, low decreasing torque 1, low decreasing torque 2, square torque |
|||
Torque Compensation |
Manual setting: 0.0~30% of rated output Automatic compensation: according to output current and motor parameter |
||||
Automatic Current-limiting and Voltage-limiting |
During acceleration, deceleration or steady running, detect automatically the current and voltage of motor stator, and control it within bounds based on unique algorithm, minimize fault-trip chance |
||||
Senseless Vector Control |
Voltage Frequency Character |
Adjust pressure/frequency ratio according to motor parameter and unique algorithm |
|||
Torque Character |
Starting torque: 3.0 Hz 150% rated torque (VF control) 0.5 Hz 180% rated torque (SVC, FVC) 0.05 Hz 180% rated torque (VC) Operating speed precision in steady state: ≤±0.5% rated synchronous speed Torque response: ≤50ms VC, SVC, FV ≤20ms |
||||
Motor Parameter Self-measurement |
Being able to detect parameter automatically under static state and dynamic state of motor, thus guarantee an optimum control. |
||||
Current and Voltage Restrain |
Current closed-loop control, free from current impact, perfect restrain function of overcurrent and overvoltage |
||||
Low Voltage Restrain during Running |
Specially for users with a low or unsteady voltage power grid: even lower than the allowable voltage range, the system can maintain the longest possible operating time based on its unique algorithm and residual energy allocation strategy |
||||
T Y P I C A L
F U N C T I O N
|
Multi-velocity and Swing Frequency Operation |
16 segments programmable multi-velocity control, multiple operation mode. Swing frequency operation: preset frequency and center frequency adjustable, parameter memory and recovery after power cut. |
|||
PID Control |
Built-in PID controller (able to preset frequency). Standard configuration RS485 communication function, multiple communication protocol for choice, synchronizing control function. |
||||
RS485 Communication |
|||||
Frequency Setting | Analog Input |
Direct voltage 0~10V, direct current 0~20mA (optional up limit and lower limit) |
|||
Digital Input |
Operation panel setting, RS485 port setting, UP/DW terminal control, or combined with analog input |
||||
Output Signal | Digital Input |
2 channel OC output and one channel relay output (TA, TB, TC), up to 16 choices |
|||
Analog Input |
2 channel analog signal output, output ranging within 0~20mA or 0~10V with flexibly setting, achievable output of physical quantities like set frequency, output frequency |
||||
Automatic Steady-voltage Operation |
Dynamic steady state, static steady state, and unsteady voltage for choices to obtain the steadiest operation |
||||
Acceleration and Deceleration Time Setting |
0.1s~3600min continuous setting, S type and linear type mode for choice |
||||
Brake |
Dynamic Braking |
Dynamic braking initial voltage, backlash voltage and dynamic braking continuous adjustable |
|||
DC Braking |
Halt DC braking initial frequency: 0.00~[P0.16] upper limit frequency Braking time: 0.0~100.0s; Braking current: 0.0%~150.0% of rated current |
||||
Flux Restraint |
0~100 0: invalid | ||||
Low Noise Running |
Carrier frequency 1.0kHz~16.0kHz continuous adjustable, minimize motor noise |
||||
Speed Tracking and Restart Function |
Smooth restart during operation, instantaneous stop and restart | ||||
Counter | A built-in counter, facilitate system integration | ||||
Operation Function |
Upper limit and lower limit frequency setting, frequency hopping operation, reversal running restraint, slip frequency compensation, RS485 communication, frequency control of progressive increase and decrease, failure recovery automatically, etc |